Hurricane Shutter Insert Anchor

Purchase Hurricane Shutter Insert Anchor

Hurricane Shutter Insert Anchor - Technical Information:

PanelMate® inserts are a fast and economical method to anchor hurricane shutters to concrete, masonry and wood. The PanelMate® inserts are available in two lengths: 2-1/4" for applications with a stucco exterior and 1-7/16” for applications without a stucco exterior.

Fastener External Thread Design:

With its over-sized ½” diameter and double-lead threads, the PanelMate® Insert drives in quickly.

Internal Threads:

Deeply tapped 1/4-20 threads (through-drilled on the short version) allow for expanded adjustability.

Internal Hex Drive:

The 5/16” internal hex drive provides strong, positive driver-bit engagement.

Special Head Style:

A flat head profile with self-cutting serrations easily counter-sinks to seat flush in stucco or other cementuous materials.

Finish: Silver Stalgard®

Tremendous corrosion resistance for long-term fastener performance.

Nylon Locking Patch:

Nylon locking patch (on the long version) helps lock the PanelMate Insert in place.

Ease of Installation:

  1. Pre-drill pilot hole with 7/16” ANSI masonry drill  bit.
  2. Drive in the PanelMate Insert until it seats flush.

NOTE: Although the PanelMate® insert can be installed with a hex screw driver, the use of the PanelMate® hex drive tool is recommended.

Material:

Carbon Steel that is case hardened for dependable thread tapping.

Performance Data:

Poured Concrete (2,700 PSI)
Test Edge Distance Embedment Ultimate Load
Pull-out 4" 1-5/8" 2,342 lbs.
Block or CMU (2,676 PSI)
Test Block Type Embedment Ultimate Load
Pull-out Grout Filled 1-1/2" 1,666 lbs.*
Hollow Block (1,794 PSI)**
Test Edge Distance Embedment Ultimate Load Typical Mode of Failure
Pull-out 1-3/4" 1-1/4" 1,376 lbs. Pop-out/spall of block
Shear 1-3/4" 1-1/4" 1,100 lbs. Break-out of block
Pull-out 3-1/2" 1-1/4" 1,608 lbs. Pop-out/spall of block
Shear 3-1/2" 1-1/4" 2,208 lbs. Break-out of block

* In-house testing was done with the pilot drilled using a corded rotary hammer and a 7/16" SDS masonry drill bit.

** In testing, the PanelMate® insert was installed and a 1/4-20 stainless steel machine screw was threaded into the insert. The test load was then applied to the machine screw.

Values shown are average ultimate values and are offered only as a guide and are not guaranteed. Reference should be made to applicable codes for the specific working ratio.