1/2" x 4-3/4" Strike Anchor, 25/Box

Not available
This product has been discontinued by the manufacturer.

1/2" x 4-3/4" Strike Anchor, 25/Box

Not available
This product has been discontinued by the manufacturer.

Purchase the quality CONFAST 1/2" x 4-3/4" Strike Anchor today, in stock and ready for same day shipment. Most orders arrive in 1 to 3 business days. SA12434
Products Features
  • POSITIVE DRIVE: Use a hammer to drive the nail to expand the anchor
  • POSITIVE SETTING: When the head of the nail meets the anchor body then the anchor is set
  • CAN SET​ ​EMBEDMENT​ ​DEPTH: Provides uniformity and consistent look when all the anchors are set
  • SLOTTED BODY IS PRECISION MATCHED TO TAPERED EXPANSION NAIL: Ensures that the anchor is uniformly expanded to provide consistent holding​ ​values in concrete
  • NUTS AND WASHERS INCLUDED: Ready to install; creates ​simple and fast installation process
Products specifications
Bit Size 1/2"
Minimum Embedment 2"
Thread Length 1-1/2"
Thread Type 1/2" - 13
2000 PSI Concrete - Pull-Out (lbs.) * 2700
2000 PSI Concrete - Shear (lbs.) * 5400
Type Male
Primary Concrete only
Diameter 1/2"
Length 4-3/4"
Material Carbon Steel Yellow Zinc
Environment Dry
Box Qty 25
Minimum Spacing 5"
Minimum Edge Distance 2-1/2"
Maximum Fixture Thickness 2-1/4"
Minimum Fixture Hole Diameter (In Place) 9/16"
Minimum Fixture Hole Diameter (Hole Spotted) 1/2"
Wrench Size For Nut 3/4"
Length Measurement End to End
Brand Name CONFAST®
Installation Video
Installing a 1/2" x 4-3/4" Strike Anchor
  1. Drill a 1/2" hole into the concrete using a carbide-tipped bit that meets ANSI Standards B212.15.
  2. Drill the hole a 1/2" deeper than the anchor will penetrate the concrete, making sure the minimum embedment requirements of 2" is met.
  3. The hole can be drilled while the fixture is in place. The minimum hole in the fixture for the 1/2" x 4-3/4" Strike Anchor is 9/16".
  4. Clean the hole with a wire brush, vacuum, compressed air, or a blow-out bulb.
  5. Put the nut and washer on the 1/2" x 4-3/4" Strike Anchor, making sure the nut is on the last threads; this will protect the threads from damage when the wedge anchor is hammered into the hole and into the concrete.
  6. Insert the anchor through the hole in the fixture and into the hole in the base material until the nut and washer are tight against the fixture.
  7. Using a properly sized hammer for the 1/2" x 4-3/4" Strike Anchor, set the pin with a number of square and sharp strikes to the head of the pin until the pin is flush with the top of the anchor. There is no need to torque the nut to set the anchor since the anchor is set with the correct set pin.
  8. Always use proper personal protective equipment per manufacturer's and OSHA instructions.

Product Reviews

* The figures above indicate average ultimate tension and shear failure values. A safety factor of 4:1 or 25% of ultimate value is generally accepted as a safe working load. Reference should always be made to applicable codes.



* The bits are recommended by diameter and may not necessarily be the length needed for your application. Please make sure the usable length will work for your application. *