ITW/Buildex®
1/4" x 6" Tapcon Flat Phillips Carbon Steel Blue Climaseal® Coated PF4-600, 100/Box
- SKU:
 - CSF146;T
 - UPC:
 - 092097902985
 - MPN:
 - PF-4600
 - Availability:
 - In Stock, Ships Today!
 
Description
Products Features 
- LOWER INSTALLATION TORQUE: Fast easy installation; saves time
 - HIGHER HOLDING VALUES: Higher quality installation; optimal holding strength
 - CLIMASEAL® COATING: Provides long-lasting rust resistance exterior
 
Products specifications 
| Bit Size | 3/16" | 
| Box Qty | 100 | 
| Minimum Embedment | 1" | 
| Thread Type | Threadform Technology™ | 
| Minimum Edge Distance | 3" | 
| Maximum Fixture Thickness | 5" | 
| Minimum Fixture Hole Diameter (In Place) | 5/16" | 
| Minimum Fixture Hole Diameter (Hole Spotted) | 5/16" | 
| Brand Name | ITW/Buildex | 
| Driver Size | #3 | 
| Minimum Spacing | 4" | 
| Thread Length | 1-3/4" | 
| 2000 PSI Concrete - Pull-Out (lbs.) * | 750 | 
| 2000 PSI Concrete - Shear (lbs.) * | 900 | 
| Length Measurement | Overall length including head | 
| Diameter | 1/4" | 
| Length | 6" | 
| Material | Carbon Steel Blue Climaseal® Coated | 
| Environment | Dry to Moist | 
| Type | Male | 
* Values shown are average ultimate values and are offered only as a guide and are not guaranteed. A safety factor of 4:1 or 25% is generally accepted as a safe working load
Installation Video 
Installing a 1/4" x 6" (six inches) Flat Phillips Tapcon® Concrete Screw - Drill a 3/16" hole into the concrete using a carbide-tipped bit that meets ANSI Standards B212.15.
 - Drill the hole a 1/2" deeper than the anchor will penetrate the concrete, making sure the minimum embedment requirements of 1" is met.
 - The hole can be drilled while the fixture is in place. The minimum hole in the fixture for the 1/4" x 6" (six inches) Flat Phillips Tapcon® Concrete Screw is 5/16".
 - Clean the hole with a wire brush, vacuum, compressed air, or a blow-out bulb.
 - Insert the point of the 1/4" x 6" (six inches) Flat Phillips Tapcon® Concrete Screw into the hole. Make sure that the screw being installed will penetrate the base material a minimum of 1" but no deeper than 1-3/4".
 - Using a #3 bit tip Phillips bit tip for the anchor , turn the screw clockwise, applying slight pressure until the head of the screw is snug against the material being fastened.
 - Always use proper personal protective equipment per manufacturer's and OSHA instructions.
 
Application Photos 

Additional Information
Bit Size:  | 
                                                    3/16"  | 
                                                
Minimum Embedment:  | 
                                                    1"  | 
                                                
Thread Length:  | 
                                                    1-3/4"  | 
                                                
Environment:  | 
                                                    Dry to Moist  | 
                                                
Material:  | 
                                                    Carbon Steel Blue Climaseal® Coated  | 
                                                
Thread Type:  | 
                                                    Threadform Technology™  | 
                                                
2000 PSI Concrete - Pull-Out (lbs.) *:  | 
                                                    750  | 
                                                
2000 PSI Concrete - Shear (lbs.) *:  | 
                                                    900  | 
                                                
Type:  | 
                                                    Male  | 
                                                
Diameter:  | 
                                                    1/4"  | 
                                                
Length:  | 
                                                    6"  | 
                                                
Box Qty:  | 
                                                    100  | 
                                                
Minimum Spacing:  | 
                                                    4"  | 
                                                
Minimum Edge Distance:  | 
                                                    3"  | 
                                                
Maximum Fixture Thickness:  | 
                                                    5"  | 
                                                
Minimum Fixture Hole Diameter (In Place):  | 
                                                    5/16"  | 
                                                
Minimum Fixture Hole Diameter (Hole Spotted):  | 
                                                    5/16"  | 
                                                
Length Measurement:  | 
                                                    Overall length including head  | 
                                                
Driver Size:  | 
                                                    #3  | 
                                                
Brand Name:  | 
                                                    ITW/Buildex  | 
                                                
            
            
                                    
Installation Document